Skip to main content

Your 5 GHz Wi-Fi Disappears for 31 Minutes. Nothing Is Broken.

A home network advertises two names. The 2.4 GHz one stays put. The 5 GHz one disappears from every device at the same moment, stays gone long enough that a reboot starts to look reasonable, then returns on its own with nothing changed. Signal strength was full beforehand, and the status page reports no fault.

In a large share of these cases nothing is broken. The 5 GHz spectrum is shared with radar, and the terms of that sharing sit in 47 CFR 15.407(h): a detection threshold, a deadline to stop transmitting, a period during which the channel may not be used again, and a check that has to pass before it may. The rule publishes those four figures separately and does not add them up. Added in the order the rule applies them, they predict how long the outage runs — and its length is the fastest way to separate a radar event from a fault.

What to Change First

If the gap cannot be tolerated, the change that ends it is to keep the 5 GHz radio out of the two bands the rule covers.

  1. Open the router's admin page and find the 5 GHz control channel setting. On ASUS firmware the documented path is Wireless → General, then the 5 GHz band. The published instruction is: "In the 5G band, uncheck [Auto select channel including DFS channels] to disable the DFS channels, and uncheck [160MHz] channel bandwidth."
  2. Set the control channel to a fixed value inside 5150–5250 MHz or 5725–5850 MHz. For reference, TP-Link's support page marks these 5 GHz channels as requiring the radar mechanism: 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136 and 140.
  3. If the channel width is 160 MHz, drop it to 80 MHz. The arithmetic below shows why 160 MHz and freedom from the rule cannot both be had here.
  4. Leave the change alone for a full day before judging it.

That trade is not free: it gives up roughly three fifths of the four 5 GHz bands compared below. Read the timing section first — if the outage does not have the shape the rule predicts, the channel is not the cause.

Time the Outage. Its Length Names the Cause.

Two observations settle almost every case, and neither needs a tool: the length of the gap, and the 5 GHz channel number before and after it.

  • Under ten seconds, same channel afterwards. Not a detection. The rule puts a flagged channel out of use for thirty minutes, so a channel carrying traffic again seconds later was not flagged. Look at client-side roaming and power saving.
  • Roughly one minute, different channel afterwards. The access point left the flagged channel for another covered one and paid the sixty-second check on arrival.
  • Under a minute, and the new channel sits in 5150–5250 or 5725–5850 MHz. The system fell back to spectrum the rule does not cover, so no check was owed. eero documents this: "If your network encounters a strike, it will automatically switch over to a non-DFS channel."
  • About half an hour or a little more, same channel afterwards. The access point was pinned to the flagged channel with nowhere to go, and waited out the full non-occupancy period and then the check.
One radar detection, four published intervals A vertical timeline with four stages. At zero seconds radar is detected at or above the threshold of minus 64 dBm for devices of 200 milliwatts to 1 watt, or minus 62 dBm for the lower power class. Within 10 seconds all transmission on the channel stops, with normal traffic permitted for at most 200 milliseconds of that window. At 30 minutes the non-occupancy period ends, measured from the moment of detection. On the reading that runs the two in series, the channel carries traffic again at 31 minutes, after a 60-second availability check. The 31-minute total is the sum of two published minima; the rule sets no order between them and does not itself print the sum. One radar detection, four published intervals Source: 47 CFR 15.407(h). Vertical axis is ordered, not to scale. t = 0 s Radar detected at or above the threshold -64 dBm for 200 mW to 1 W e.i.r.p.; -62 dBm for the lower-power class by t = 10 s All transmission on that channel ceases Normal traffic allowed for at most 200 ms of that window, or 2 percent of it t = 30 min Non-occupancy period ends Measured from detection, so the 10-second stop sits inside it t = 31 min Channel may carry traffic again On the series reading, the 60-second check follows the non-occupancy period 31 minutes = 30 minutes + 60 seconds Both are minima, and the rule sets no order between them. The sum is one reading.

Where the 31 Minutes Comes From

Each figure is quoted in full below, because each carries a qualifier that changes what it means.

  • The threshold. "The minimum DFS detection threshold for devices with a maximum e.i.r.p. of 200 mW to 1 W is −64 dBm. For devices that operate with less than 200 mW e.i.r.p. and a power spectral density of less than 10 dBm in a 1 MHz band, the minimum detection threshold is −62 dBm. The detection threshold is the received power averaged over 1 microsecond referenced to a 0 dBi antenna."
  • The stop. "After a radar's presence is detected, all transmissions shall cease on the operating channel within 10 seconds. Transmissions during this period shall consist of normal traffic for a maximum of 200 ms after detection of the radar signal. In addition, intermittent management and control signals can be sent during the remaining time to facilitate vacating the operating channel."
  • The wait. "A channel that has been flagged as containing a radar system, either by a channel availability check or in-service monitoring, is subject to a non-occupancy period of at least 30 minutes. The non-occupancy period starts at the time when the radar system is detected."
  • The check. "A U-NII device shall check if there is a radar system already operating on the channel before it can initiate a transmission on a channel and when it has to move to a new channel. The U-NII device may start using the channel if no radar signal with a power level greater than the interference threshold values listed in paragraph (h)(2) of this section, is detected within 60 seconds."

The non-occupancy period is measured from the moment of detection, which places the ten-second stop inside it rather than after it. And the check is owed "before it can initiate a transmission on a channel and when it has to move to a new channel", so returning to the flagged channel once the thirty minutes are up still costs sixty seconds. What the rule does not settle is whether the two run in series. It sets no order between them, and it does not say that a check which only listens may not run inside the non-occupancy period. Read in series — thirty minutes, then sixty seconds — the channel carries traffic again 31 minutes after detection. That is the reading this article uses.

Two secondary figures fall out of the same quotations. The two hundred milliseconds of normal traffic permitted during the stop is 2 percent of the ten-second window. And the 2 dB between the two thresholds is a factor of about 1.58 in received power, so a router in the lower-power class may lawfully ignore a return that one in the higher-power class must act on.

Which Channels the Rule Covers, and What Leaving Them Costs

Paragraph (h)(2) is specific about where it applies: "U-NII devices operating with any part of its 26 dB emission bandwidth in the 5.25-5.35 GHz and 5.47-5.725 GHz bands shall employ a DFS radar detection mechanism to detect the presence of radar systems and to avoid co-channel operation with radar systems." Two bands, named by frequency rather than by channel number. Paragraph (a) allocates two further 5 GHz bands that (h)(2) does not name, 5150–5250 MHz and 5725–5850 MHz, plus a more narrowly conditioned 5850–5895 MHz and the 6 GHz allocations running to 7.125 GHz.

How much of these four 5 GHz bands the radar rule covers A horizontal band map of four bands, from 5150 to 5850 megahertz. The 5150 to 5250 block of 100 megahertz and the 5725 to 5850 block of 125 megahertz are not covered by the radar detection rule. The 5250 to 5350 block of 100 megahertz and the 5470 to 5725 block of 255 megahertz are covered. The stretch from 5350 to 5470 is not allocated to unlicensed use by this section. Covered spectrum totals 355 megahertz against 225 megahertz not covered, which is 61.2 percent of the 580 megahertz these four bands total. A fifth band, 5850 to 5895 megahertz, is not mapped here; counting it on the uncovered side gives 355 of 625 megahertz, or 56.8 percent. The widest uncovered block is 125 megahertz, so no 160 megahertz channel fits inside uncovered spectrum. How much of these four 5 GHz bands the radar rule covers Band edges from 47 CFR 15.407(a) and (h)(2). Widths drawn to scale. 100 MHz 100 MHz no U-NII 255 MHz 125 MHz 5150 5250 5350 5470 5725 5850 Frequency in MHz radar rule applies rule does not apply Covered: 100 + 255 = 355 MHz. Not covered: 100 + 125 = 225 MHz. 355 of 580 MHz is 61.2 percent of the four bands mapped above. Adding 5850-5895 MHz, not mapped here, gives 355 of 625 = 56.8 percent. One 80 MHz channel fits in each uncovered block, so exactly two exist. 160 > 125, so no 160 MHz channel fits inside uncovered spectrum at all.

The covered bands, 5250–5350 MHz and 5470–5725 MHz, are 100 MHz and 255 MHz wide, for 355 MHz; the uncovered ones are 100 MHz and 125 MHz, for 225 MHz. Of the 580 MHz those four bands total, the rule reaches 61.2 percent. Adding the separately conditioned 5850–5895 MHz band to the uncovered side gives 56.8 percent, changing the number and not the conclusion.

The widest uncovered block is 125 MHz. An 80 MHz channel fits inside each uncovered block, giving exactly two across the whole range; a 160 MHz channel fits inside neither, because 160 is larger than 125. Any 160 MHz channel here therefore overlaps covered spectrum, and (h)(2) applies to a device with "any part of its 26 dB emission bandwidth" in those bands. ASUS pairs the two settings in the instruction quoted earlier and gives no reason for pairing them.

What the Router's Own Log Should Say

Nothing in the rule requires that a record be kept, so a log line is confirmation when present and nothing when absent. A clock needs no log: the minute the 5 GHz name leaves a phone and the minute it returns bound the gap from outside. Two values on the wireless settings page decide the rest — the control channel number, and the channel width that may have put it in covered spectrum.

The Rule Puts the Waiting on the Router, Not the Phone

One line explains why the client side looks like nothing at all. The rule assigns requirements by operational mode: "(A) The requirement for channel availability check time applies in the master operational mode. (B) The requirement for channel move time applies in both the master and slave operational modes."

The access point is the master, and the availability check is assigned to that mode alone. A laptop or phone is a slave device, and the requirement the list extends to it is the channel move time. The list allocates requirements between modes and says nothing about what a client displays. What a phone shows is the consequence of the access point having stopped transmitting: the network reads as absent rather than failed, so a person looking at the phone will keep looking at the phone.

Who waits, and what each outage length means Two panels compare the access point in master mode, which runs the 60-second availability check, ceases transmitting within 10 seconds and sits out the 30-minute non-occupancy period, with the client device in slave mode, to which the channel move time applies, to which the availability check does not apply, and which the list does not ask to report anything. Below, three outcomes read from the length of the gap together with the channel the network returns on: a gap of about 60 seconds with a changed channel means a move to another covered channel; a gap of about 31 minutes on the same channel means the access point was pinned to the flagged channel; a gap under 10 seconds that ends on the same channel means the channel was never flagged. Who waits, and what each outage length means Requirements in 47 CFR 15.407(h)(2). (h)(2)(i) assigns the check and the move time by mode. Access point, master mode Runs the 60-second availability check Ceases transmitting within 10 seconds Sits out the 30-minute non-occupancy period Client device, slave mode Channel move time applies Availability check does not apply The list asks it to report nothing Gap about 60 s Channel number changed Moved, then checked Gap about 31 min Same channel afterwards Pinned, waited it out Gap under 10 s Same channel afterwards Never flagged: look elsewhere

When This Doesn't Apply

The pattern above is narrow, and several common complaints look similar without being the same thing.

  • A 6 GHz network that drops with it. Paragraph (h)(2) names only the two 5 GHz bands, so the 6 GHz allocations are outside it. If a network that also advertises a 6 GHz name loses that one at the same instant, something else took both radios down.
  • Drops every few minutes. The non-occupancy period is "at least 30 minutes", so a device cannot lawfully cycle faster on a channel it has flagged. A five-minute rhythm is a different fault.
  • The 2.4 GHz name goes too. Nothing in this paragraph touches 2.4 GHz; losing both bands together points at power, the uplink, or the router.
  • A long gap right after a restart. ASUS states that "The Channel Availability Check process would take 1-10 minutes depending on the country." The upper end is ten times the sixty-second United States floor, so a router coming up on a covered channel can hold the name back for minutes with nothing detected.
  • Two routers in one house disagreeing. The threshold is −64 dBm for one power class and −62 dBm for the other, so one access point going quiet while another stays up is consistent with the rule.
  • Treating 31 minutes as exact. Both components are minima: "at least 30 minutes", and a check that clears if nothing is detected "within 60 seconds". The rule also sets no order between them, so 31 minutes is one reading rather than a floor the rule states. A second detection during the wait produces a longer gap.

The Short Checklist

  1. Write down the minute the 5 GHz name disappears and the minute it returns.
  2. Record the 5 GHz control channel number before the gap and after it.
  3. Match the pair against the four rows above.
  4. Open the router's system log for a line naming radar or DFS at that timestamp. Its presence confirms the reading; its absence does not refute it.
  5. Then choose deliberately. Covered channels buy 61.2 percent of the four bands compared above and accept gaps of thirty minutes or more; 5150–5250 and 5725–5850 MHz leave 225 MHz, two 80 MHz channels, and no 160 MHz option.

Neither choice is a repair, because nothing is broken. This spectrum was allocated on the condition that the network yields to radar, and the rule states the terms of yielding in four numbers.

Comments

Popular posts from this blog

Samsung TV Keeps Signing Out of YouTube After a Firmware Update: Six Checks

A Samsung smart TV that has held a YouTube session for a year can begin showing the sign-in screen every time the screen wakes. The same Google Account still works on a phone, and other apps on the same television stay signed in. Entering the account again works, and then the television forgets again a day or a week later. The fastest route out of this is to stop treating it as a television fault until the account side has been ruled out. A YouTube sign-in on a television is not a file kept on the television. Google lists it in the account as a grant named YouTube on TV , and YouTube's own support page states that removing that grant "will sign you out of any device using the YouTube on TV app with that account." A television cannot hold a session that the account has already released. Six checks follow, in cost order. The first three are done from a phone, take about seven minutes, and require no television menus at all. Only when all three come back clean is there r...

Ads Keep Playing While the YouTube Premium Membership Page Still Shows the Plan Active

A YouTube Premium charge clears every month, the purchases page lists the plan, and a pre-roll ad still runs before the video. Sometimes it happens on one device only. Sometimes it happens on every device at once. Sometimes it started on a specific date with no change to the account at all. Cancelling and re-subscribing is the wrong first move, and it is the one most people make. Re-subscribing on the account that is already paying changes nothing, and re-subscribing on a different account creates a second charge while the ads continue. The benefit is not a switch on the plan. It is a chain of four separate conditions, and an ad appears the moment any one of them fails. Work the chain in order: which account is signed in on the exact surface showing the ad, which product the plan line names, whether that plan is currently paid and eligible, and whether the app in front of you is one the benefit reaches. Most cases resolve at the first or third link, and both are readable in under t...

When an Amazon Order Sits at "Preparing for Shipment" Past the Delivery Estimate

An Amazon order that has read Preparing for Shipment for eight or nine days, with no tracking number and an estimated delivery date already behind it, is not going to move because the order page gets refreshed again. Three facts decide what can still be done, and the status label is not one of them: who is actually shipping the order, whether the order has entered the shipping process, and how far past the estimated delivery date the clock has run. Every number, menu path and time window below comes from Amazon's own customer help pages, checked in August 2026. Where Amazon publishes no answer, that gap is stated rather than filled in with a plausible-sounding one. Start With the Seller Line, Not the Status Line Open Your Orders and read the two lines under the product title rather than the status banner above it. An order that says Ships from Amazon and Sold by Amazon.com follows one set of published rules. An order sold and shipped by a marketplace seller follows a diff...